Introduction:Gene amplification instrument PCR instrument gradient type fully considers the special requirements of PCR experiments,and has carried out a targeted design for the temperature control of the instrument,......
PCR amplification instrument, also known as PCR gene amplification instrument, PCR nucleic acid amplification instrument, polymerase chain reaction nucleic acid amplification instrument, is a kind of amplification of specific DNA using PCR (Polymerase chain reaction, polymerase chain reaction) technology equipment.
Features:
1. Imported core parts, guaranteed quality and life,
2. 7-inch high-resolution color large screen, easy to operate
3. Excellent temperature uniformity, the best experimental results can be obtained
4. Support Chinese and English, users can switch freely
5. Unlimited download of programs via U disk
6. Hot lid repressurization technology, no matter how many sets of sample tubes are running, it can keep the sample tube pressure constant, and the sample tube is in close contact with the sample stage
7. Support Chinese and English, users can switch freely
Application field
It is widely used in medical and biological laboratories, for example, it is used to determine whether the sample will show a genetic disease map, the diagnosis of infectious diseases, gene replication, and paternity testing.
PCR instrument parameters:
Main parameters | Parameter range | ||
Model | THT96G (gradient type) | THT96 (standard type) | THT48 (standard type) |
Temperature rise and fall technology | Semiconductor refrigeration | ||
LCD | 7-inch true color screen, curve graph display program | ||
U disk function | Unlimited download of programs via U disk | ||
Communication Interface | USB2.0*2 RS232 | ||
Support mouse | Use multi-user names; | ||
Computer connection | Password protection Wireless connection, one computer can connect 100 PCR instrument at the same time; The cable connection | ||
Support mouse | Have | ||
Language | Support Chinese and English | ||
Sample stage capacity | 0.2ml*96 hole | 0.2ml*48 hole | |
Sample stage temperature range | 0℃-100℃ | ||
Maximum heating rate | 5℃/Second | ||
Maximum cooling rate | 5℃/Second | ||
Temperature uniformity of sample stage | ≤±0.2℃ | ||
Temperature accuracy of sample stage | ≤±0.2℃ | ||
Temperature display resolution | 0.1℃ | ||
Temperature control method | Analog tube + sample stage | ||
Variable temperature speed adjustable | Have | ||
Gradient temperature accuracy | ≤±0.2℃ | None | |
Gradient temperature uniformity | ≤±0.2℃ | None | |
Gradient range | 30℃-100℃ | None | |
Temperature range | 0-30℃ | None | |
Number of program storage | The instrument can store 120 programs, and can download unlimited programs via U disk | ||
Maximum number of steps | 40, can do multiple nested loops | ||
Maximum number of cycles | 100 standard loops (up to 60,000 nested loops) | ||
Time increase/decrease | 1-120 seconds, can do Long PCR experiment | ||
Temperature increase/decrease | 0.1-10.0℃, can do Touchdown PCR experiment | ||
Auto pause | Have | ||
Power failure protection | Have | ||
heat preservation | Infinite holding time | ||
Run time display | Have | ||
Real Time Clock | Have | ||
Hot lid temperature | 30℃-110℃ adjustable | ||
Heat cover height | Stepless free adjustment, adapt to different PCR tubes | ||
Hot lid repressurization technology | Two levels of adjustment, no matter how many sample tubes are running during the experiment, the pressure of the sample tube can be kept constant | ||
The hot lid closes automatically | When the set temperature of the sample stage is lower than 30℃ or the program ends, it will automatically shut down | ||
Input power, power | Universal power supply (220VAC/47-65Hz), 200W-600W | ||
Size, net weight | 303mm*243mm*273mm,9Kg | ||
notepad | Have | ||
Tm value calculated | Have | ||
More sample table capacity | 0.2ml*96 hole+0.5ml*77 hole, 0.2ml*48 hole+0.5ml*48 hole 0.2ml*108 hole +0.5ml*88 hole,0.2ml*384 hole,0.2*48 hole,0.2ml*32 hole。Can add, |