Model:JX-QE-CL
Brand:Shanghai Jingxin
Specifications :One Set
Introduction:Product introduction: Shanghai Jingxin®'s JX-QE-CL®QuEChERS pre-processing all-in-one machine (patented product, counterfeiting must be punished! ZL2017305264903) is a special, fast, efficient, multi-test tube consistent system.
Shanghai Jingxin®'s JX-QE-CL®QuEChERS pre-processing all-in-one machine (patented product, counterfeiting must be punished! ZL2017305264903) is a special, fast, efficient, multi-test tube consistent system. It can extract and purify the original DNA, RNA and protein from any source (including soil, plant and animal tissues/organs, bacteria, yeast, fungi, spores, paleontological specimens, etc.).
Technical parameter:
Main parameters | Parameter range |
Application areas: | tissue homogenization, grinding, cell disruption, homogenization, material dispersion, preparation, sample mixing, shaking |
Sample processing: | It can handle 64 samples at the same time in 15 seconds, including liquid nitrogen refrigeration adapters that can be used for 12 and 24 positions |
Compatible sample volume: | 64*(0.2-0.5ML)/64*2ML/12*(5-15)ML/4*25ML/2*50ML, various specifications of grinding tubes can be customized |
Touch screen display: | convenient and intuitive operation |
Data storage: | Ten groups of experimental data can be stored. According to different experimental samples, animal heart, spleen, lung, kidney, bone, skin, and hair modes are set. |
Mode cycle: | According to the set experimental parameters, it can continuously circulate among several set parameters to further reduce the interference of human factors |
Feeding size: | No requirement, adjust according to adapter |
Refrigeration function: | Yes, adjustable from -30 degrees to 37 degrees |
Temperature control accuracy: | +0.5 degrees |
Open cover operation protection: | electromagnetic lock |
Discharge size: | ~5µm |
The number of grinding platforms (the number of grinding tanks that can be accepted) | >2 |
Fastening device with automatic centering | support |
Homogenization speed and time: | 0—70 HZ/sec, working time: 0 seconds to 9999 minutes, users can set by themselves; |
Diameter of grinding ball: | 0.1-30mm |
Grinding ball material: | alloy steel, chromium steel, zirconia, tungsten carbide, quartz sand; |
Acceleration: | reach a greater speed in 2 seconds |
Deceleration: | reach a lower speed in 2 seconds |
Noise: | <55db |
Grinding method: | wet grinding, dry grinding and low temperature grinding are all available |
Refrigeration: | It has the ability to upgrade to ultra-low temperature liquid nitrogen refrigeration or air refrigerator refrigeration |
Adapter material: | PTFE or alloy steel |
Full protection: | Fastening device with automatic center positioning, safety lock during work, full protection |
Grinding kit material: | hard rigid, PTFE (Teflon) zirconia |
Dimensions: | 630mm*300mm*480mm |
Weight: | 58KG |
◆ Basic configuration:
1. A set of JX-QE-CL system machines.
2. Freeze grinding module 1.5-2.0ml*24 set, 7-10ml*8 set, 25ml*2 set.
3. PTFE tube 15ml, a set of 15ml. A set of 25ml stainless steel grinding tank, a set of 25ml PTFE
4. One bottle of ceramic beads for grinding and one bottle of stainless steel beads.
Typical application:
Typical application one, QUECHERS method of rapid sample pretreatment for pesticide residue inspection:
1. JX-QE16 automatic QuEChERS pre-processing all-in-one machine homogenizes 10g of samples and adds 10ml of acetonitrile;
2. JX-QE16 automatic QuEChERS pre-processing all-in-one machine oscillates for 1 min, add 1g of sodium chloride and 4g of magnesium sulfate;
3. The JX-QE16 automatic QuEChERS pre-processing integrated machine oscillates for 1 min and centrifuges at 5000 rpm for 10 min to aliquot 1 ml of the acetonitrile layer and add 250 mg of magnesium sulfate 150 mg PSA powder;
4. The JX-QE16 automatic QuEChERS pre-processing integrated machine oscillates for 1 min, and the supernatant is centrifuged and analyzed by GCMS.
Typical application 2: LC/MS method for extracting OTC drugs in water and sludge cake:
1), sample preparation
Put 3.76mL water, 20uL cetirizine, diphenhydramine and diclofenac, and 140μL acetaminophen into a 50ml centrifuge tube. For the sludge sample experiment, weigh the 2.5k freeze-dried sludge and add the same amount of water and medicine as mentioned above. Add 10mL acetonitrile and add it to the EN extraction tube. After JX-QE16 works with a 50ML adapter for 1 minute, it is centrifuged at 4000rpm for 5 minutes.
To
Dispersive solid-phase extraction: Take the supernatant (about 7mL) and place it in the d-SPE dispersive solid-phase extraction package. Use the 15ML adapter for JX-QE16 for 1 minute, and then centrifuge at 4000 rpm for 5 minutes. Then the extracted supernatant was transferred to a clean 15mL centrifuge tube and evaporated to dryness with nitrogen. Use 1.875 mL of 50:50 acetonitrile and water to make a sample solution.