Model:KZ-II
Brand:Shanghai Jingxin
Specifications :KZ-II
Introduction:Shanghai Jingxin®'s KZ-II® series tissue grinder is a special, fast, efficient, multi-tube consistent system. It can extract and purify the original DNA, RNA and protein from any source.
Want to cryogenically grind samples?
Too long grinding time causes sample deterioration?
Is the sample grinding effect unsatisfactory?
The grinder is too noisy and turbulent when it is working?
New products are coming!
Shanghai Jingxin's low-temperature multi-sample high-speed tissue grinding machine (patented product, counterfeiting will be punished! 201620363493X) will solve your troubles of grinding samples in an all-round way!
Advantage 1: Grinding of 2×24, 2×48, 4×96 samples within 1 minute, shorter time and faster operation!
Advantage 2: It can be frozen or ground at room temperature, just that way!
Advantage 3: Special three-dimensional integrated oscillation mode, which can crush samples in all directions!
Advantage 4: When the grinder is working, there is no noise or shaking
The new upgrade!
Say goodbye to the horizontal grinder of the old age!
KZ-II series multi-sample tissue grinder/high-throughput tissue grinder
1. Large research sample size: 24 samples can be ground within 1 minute
2. Avoid cross-contamination between samples: disposable grinding tubes and grinding beads are used in the grinding process, and the samples are in a fully enclosed state during the grinding process, avoiding cross-contamination between samples
3. Easy to operate: you can directly select the grinding time and grinding frequency to change the grinding conditions
4. Good safety: with cover opening protection device, emergency stop button, little vibration during the operation of the instrument
5. Strong reproducibility: the same batch of samples adopts the same grinding conditions, and the grinding effect is the same
6. Easy to use: it can be centrifuged directly after grinding, no need to change the centrifuge tube
The KZ-II® series tissue grinder of Shanghai Jingxin® is a special, fast, high-efficiency, multi-test tube consistent system. It can extract and purify the original DNA, RNA and protein from any source (including soil, plant and animal tissues/organs, bacteria, yeast, fungi, spores, paleontological specimens, etc.).
Technical features:
Compared with other existing sample preparation methods, the KZ-II® system has the advantages of wide versatility, high efficiency and flexibility. The system avoids the laborious, time-consuming, low-efficiency and many other shortcomings of traditional methods such as grinding, homogenization, and ultrasonic treatment, and can efficiently, quickly and stably lyse and purify nucleic acids and proteins of various types of samples.
This machine is also known as multi-sample tissue grinder, rapid tissue grinder, multi-sample tissue homogenizer, and rapid sample homogenization system.
Grindable samples:
1. Plant tissue: roots, stems, leaves, flowers, fruits, seeds, etc.
2. Animal tissue: brain, heart, lung, stomach, liver, thymus, kidney, intestine, lymph node, muscle, bone, etc.
3. Fungal bacteria: yeast, E. coli, etc.
4. Food and medicine: all kinds of food, tablets, etc.
5. Volatile samples: coal, oil shale, wax products, etc.
6. Plastics, polymers: PE, PS, textiles, resins, etc.
Grinding comparison:
*For more comparison effects of grinding, please call us for details.
Operating procedures:
Features:
The KZ-II® series grinder adopts a special three-dimensional integrated vibration mode of up and down and left and right shaking. The sample moves in a three-dimensional shape in the space of a figure of eight, through the high-frequency reciprocating vibration of the grinding beads (zirconia, steel balls, glass beads, ceramic beads) , Impact, shear. Achieve goals quickly. Make the ground samples more sufficient, more uniform, better sample repeatability, and no cross-contamination between samples
1. The number of operations is large and the effect is good
Efficient and fast work can complete the grinding of 2×24, 2×48, 4×96 samples in 1 minute. Save time and effort, with small differences between batches and within batches. The extracted protein has higher specific activity and longer nucleic acid fragments.
2. No cross contamination
The sample tube is in a fully enclosed state during the crushing process, and disposable centrifuge tubes and beads can be used. The sample is kept in the tube completely to avoid cross-contamination between samples and external contamination.
3. Easy to operate
3.1 The built-in program controller can set parameters such as grinding time and rotor vibration frequency;
3.2 Humanized operation interface.
4. Good stability
4.1 Adopting a special three-dimensional integrated vibration mode of up and down and left and right shaking, the sample moves in a three-dimensional shape of a figure of 8 in the space, the grinding is more sufficient, and the stability is better;
4.2 During the operation of the instrument, the noise is less than 55dB, which will not interfere with other experiments or instruments.
5. Convenient for low temperature operation
When a low-temperature grinding environment is required, the adapter with the sample can be immersed in liquid nitrogen to cool for 1-2 minutes, and then moved to the host to quickly fix it to start grinding. There is no need to freeze again, which saves liquid nitrogen.
6. Good repeatability
The same procedure is set for the same tissue sample to obtain the same grinding effect. Short working time, sample temperature will not rise
Product parameters:
The main parameters | Parameter range |
Application | Tissue homogenization, grinding, cell disruption, homogenization, material dispersion, preparation, sample mixing, shaking |
Sample processing: | It can handle 24 samples at the same time in 15 seconds, including liquid nitrogen refrigeration adapters that can be used for 12 and 24 positions |
Compatible sample volume: | 24*(0.2-0.5ML) /24*2ML /8*(5-15)ML /4*25ML /2*50ML, various specifications of grinding tubes can be customized |
Touch screen display: | Touch screen display for convenient and intuitive operation |
Storing data: | Ten sets of experimental data can be stored, and animal heart, spleen, lung, kidney, bone, skin, and hair modes are set according to different experimental samples. |
Pattern cycle: | According to the set experimental parameters, it can continuously circulate among several set parameters to further reduce the interference of human factors |
Anti-vibration principle: | KZ-1 innovative anti-vibration principle, as well as a special three-dimensional integrated vibration mode of up and down and left and right shaking, the sample moves in a three-dimensional shape in the space, and the innovative grinding bead movement method ensures the idealization of sample processing and instant crushing effect |
Feed size | No requirement, adjust according to adapter |
Discharge size | ~5µm |
The number of grinding platforms (the number of grinding tanks that can be accepted) | >2 |
Fastening device with automatic center positioning | Yes |
Homogenization speed: | 0—70 HZ/sec, working time: 0 second to 9999 minutes, users can set by themselves; |
Diameter of grinding ball: | 0.1-30mm |
Grinding ball material: | Alloy steel, chromium steel, zirconia, tungsten carbide, quartz sand; |
Accelerate: | Achieve greater speed in 2 seconds |
Decelerate | Achieve greater speed in 2 seconds |
Noise level | <55db |
Grinding method: | Wet grinding, dry grinding and low temperature grinding are all available |
Refrigeration: | Has the ability to upgrade to ultra-low temperature liquid nitrogen refrigeration or air refrigerator refrigeration |
Adapter material: | PTFE or alloy steel |
Full protection: | Fastening device with automatic center positioning, safety lock when working, full protection |
Grinding kit material: | Hard steel, PTFE (Teflon) zirconia |
Dimension | 450*500*580 |
Weight | 55KG |
Basic configuration:
Ø One KZ-II® host | Ø One set of 2ml adapter, one set of 2ml refrigeration adapter, one set of 2ml refrigeration fluid adapter (optional) |
|
|
Ø 1000 5MM grinding beads. 1000 5MM ceramic grinding beads | Ø One set of special bead gun (optional) |
|
|
Remark:
* The supporting jingxin kit can be used to extract DNA/RNA proteins in samples quickly, efficiently, stably and in batches
* 1HZ=30 rev/sec 1HZ=100RPM
* Conventional adapters can be placed in the refrigerator to provide a cold environment for the samples while working. It can be equipped with an adapter with refrigeration, which can be immersed in liquid nitrogen for more than 30 minutes.
* The noise emission value for the working environment depends on the type of sample and the setting of the grinder. The parameters in the table are in no-load state
* A small amount of samples usually used for DNA and RNA separation can be prepared in disposable centrifuge tubes. Adapters made of polytetrafluoroethylene materials can be used to accommodate 5 or 10 disposable sample tubes for cell disruption. In multi-sample tissue The cell tissue in the grinder is quickly and effectively broken in a very short time, so there is no need for additional low-temperature refrigeration
Experimental case:
1. Test method for grinding citrus peel tissue with Tissuelyser® plant tissue grinder | 2. Test method for grinding rice leaves with Tissuelyser® plant tissue grinder |
|
|
Optional accessories:
Shanghai Jingxin is equipped with complete DNA, RNA and protein extraction kits for various samples of animals, plants, microorganisms, etc., which can extract target components quickly, efficiently, stably and in batches
Extract objects | Jingxin supporting kit | |
Animal tissue | DNA | jingxin-1 |
RNA | jingxin-2 | |
Protein | jingxin-3 | |
Plant tissue | DNA | jingxin-4 |
RNA | jingxin-5 | |
Protein | jingxin-6 | |
Microorganism | DNA | jingxin-7 |
RNA | jingxin-8 | |
Protein | jingxin-9 |