Model:Tissuelyser-192
Brand:Shanghai Jingxin®
Specifications :192 bits
Introduction:Shanghai Jingxin® Tissuelyser® tissue grinder is a special, fast, efficient, multi-tube consistent system. It can extract and purify the original DNA, RNA and protein from any source.
Product Description:
Shanghai Jingxin® Tissuelyser® tissue grinder (patented product, counterfeiting must be punished! 201620363493X) is a special, fast, efficient, multi-tube consistent system. It can extract and purify the original DNA, RNA and protein from any source (including soil, plant and animal tissues/organs, bacteria, yeast, fungi, spores, paleontological specimens, etc.).
This machine is also known as multi-sample tissue grinder, rapid tissue grinder, multi-sample tissue homogenizer, and rapid sample homogenization system.
Technical features:
Compared with other existing sample preparation methods, the Tissuelyser® system has the advantages of wide versatility, high efficiency and flexibility. The system avoids the laborious, time-consuming, low-efficiency and many other shortcomings of traditional methods such as grinding, homogenization, and ultrasonic treatment, and can efficiently, quickly and stably lyse and purify nucleic acids and proteins of various types of samples.
Grindable samples:
1. Plant tissue: roots, stems, leaves, flowers, fruits, seeds, etc.
2. Animal tissue: brain, heart, lung, stomach, liver, thymus, kidney, intestine, lymph node, muscle, bone, etc.
3. Fungal bacteria: yeast, E. coli, etc.
4. Food and medicine: all kinds of food, tablets, etc.
5. Volatile samples: coal, oil shale, wax products, etc.
6. Plastics, polymers: PE, PS, textiles, resins, etc.
Operating procedures:
Features:
The Tissuelyser® series grinder adopts a special vertical up and down integrated vibration mode, through the high frequency reciprocating vibration, impact and shearing of the grinding beads (zirconia, steel balls, glass beads, ceramic beads). Achieve goals quickly. Make the ground samples more sufficient, more uniform, better sample repeatability, and no cross-contamination between samples .
1. The number of operations is large and the effect is good
Efficient and fast work can complete the grinding of 2×24, 2×48, 4×96 samples in 1 minute. Save time and effort, with small differences between batches and within batches. The extracted protein has higher specific activity and longer nucleic acid fragments.
2. No cross contamination
The sample tube is in a fully enclosed state during the crushing process, and disposable centrifuge tubes and beads can be used. The sample is kept in the tube completely to avoid cross-contamination between samples and external contamination.
3. Easy to operate
3.1 The built-in program controller can set parameters such as grinding time and rotor vibration frequency;
3.2 Humanized operation interface.
4. Good stability
4.1 The vertical oscillation method is adopted for more sufficient grinding and better stability;
4.2 During the operation of the instrument, the noise is less than 55dB, which will not interfere with other experiments or instruments.
5. Convenient for low temperature operation
When a low-temperature grinding environment is required, the adapter with the sample can be immersed in liquid nitrogen to cool for 1-2 minutes, and then moved to the host to quickly fix it to start grinding. There is no need to freeze again, which saves liquid nitrogen.
6. Good repeatability
The same procedure is set for the same tissue sample to obtain the same grinding effect. The working time is short, and the sample temperature will not rise.
Grinding comparison:
Product parameters:
The main parameters | Parameter range |
Application | Tissue homogenization, grinding, cell disruption, homogenization, material dispersion, preparation, sample mixing, shaking |
Sample processing: | The maximum processing capacity within 15 seconds can process 96 samples at the same time, suitable for 12-position and 24-position liquid nitrogen refrigeration adapters |
Compatible sample volume: | 384*(0.2-0.5ML) /192*2ML /48*5ML/24*(7-15)ML /4*25ML /2*50ML/2*100ML, various specifications of grinding tubes can be customized |
Touch screen display: | Can be convenient and intuitive operation, and can be upgraded to touch screen display operation |
Anti-vibration principle | German innovative schleifen-1 working method, innovative anti-vibration principle, and vertical up and down movement, and innovative grinding bead movement, ensure the idealization of sample processing and instant crushing effect. |
Feed size | No requirement, adjust according to adapter |
Discharge size | ~5µm |
Number of grinding platforms (the number of grinding tanks that can be accepted): | 1-2 (acceptable grinding jar) |
Number of samples: | Random 2×48(1-2ml); optional 4×96(0.5ml tube), 2×70(0.5ml single tube), 2×24(5ml) |
Strong versatility, configurable grinding tank volume: | 8ml / 10ml / 25 ml / 50ml / 100ml / (optional) |
Fastening device with automatic center positioning | Yes |
Fixture stroke: | 32mm |
Homogenization speed: | 0—70 HZ/秒, 0—70 HZ/S |
Operating hours : | 0 seconds -9999 minutes, users can set by themselves; |
Diameter of grinding ball: | 0.1-30mm |
Grinding ball material: | Alloy steel, chromium steel, zirconia, tungsten carbide, quartz sand; |
Accelerate: | Achieve greater speed in 2 seconds |
Decelerate | Achieve greater speed in 2 seconds |
Noise level: | <55db |
Grinding method: | Wet grinding, dry grinding and low temperature grinding are all available |
Refrigeration: | Has the ability to upgrade to ultra-low temperature liquid nitrogen refrigeration or air refrigerator refrigeration |
Adapter material: | PTFE or alloy steel |
Full protection: | Safety lock during work, full protection |
Grinding kit material: | Hard steel, PTFE (Teflon) zirconia |
Dimension | 400*520*660 |
Weight | 60 KG |
Basic configuration:
Ø One Tissuelyser® host | Ø One set of 2ml adapter, one set of 2ml refrigeration adapter, one set of 2ml refrigeration fluid adapter (optional) |
|
|
Ø 1000 5MM grinding beads. 1000 5MM ceramic grinding beads | Ø One set of special bead gun (optional) |
|
|
Experimental case:
1. Application of automatic grinder in animal sample processing | 2. Test method for grinding celery stem tissue with Tissuelyser plant tissue grinder |
|
|
Shanghai Jingxin is equipped with complete DNA, RNA and protein extraction kits for various samples of animals, plants, microorganisms, etc., which can extract target components quickly, efficiently, stably and in batches.
Optional accessories:
Shanghai Jingxin is equipped with complete DNA, RNA and protein extraction kits for various samples of animals, plants, microorganisms, etc., which can extract target components quickly, efficiently, stably and in batches.
Extract objects | Jingxin supporting kit | |
Animal tissue | DNA | jingxin-1 |
RNA | jingxin-2 | |
Protein | jingxin-3 | |
Plant tissue | DNA | jingxin-4 |
RNA | jingxin-5 | |
Protein | jingxin-6 | |
Microorganism | DNA | jingxin-7 |
RNA | jingxin-8 | |
Protein | jingxin-9 |